en
  • lt
  • en

JUMO pH, ORP and conductivity simulators and calibration adapters

Process analyzers and sensors, Water analysis

Fields of application

JUMO measurement signal simulators and calibration adapters for testing pH, ORP and conductivity measurement systems. Used during commissioning, calibration and maintenance of devices. Allows you to check measuring transducers, controllers and connecting cables and identify possible faults.

 

Features:

  • Three versions for pH/ORP and conductivity measurement systems
  • Simulation of pH values from 0 to 14
  • Redox potential simulation from –414 to +414 mV
  • Conductivity signal simulation up to 800 mS/cm
  • Simulation of Pt100 temperature sensor at +25 and +75 °C
  • High impedance mode for testing cables and moisture-induced faults
  • Inductive conductivity calibration adapter for JUMO AQUIS 500 Ci systems
  • SPECIFICATIONS
  • AVAILABLE MODELS
  • DOCUMENTS

SPECIFICATIONS

  • Device type

    Measurement signal simulator/calibration adapter
  • Available versions

    pH/ORP simulator; contact conductivity simulator; inductive conductivity calibration adapter
  • pH simulation range

    0-14 pH
  • pH simulation step

    1 pH
  • ORP simulation range

    –414 to +414 mV
  • ORP simulation step

    59 mV
  • pH/ORP simulation accuracy

    ±1 % simulation range
  • pH/ORP output impedance

    1 kΩ or 1000 MΩ
  • Contact conductivity simulation range

    From 40 nS/cm to approximately 800 mS/cm, depending on the cell constant
  • Supported cell constants

    K = 0.01; 0.1; 1.0; 3.0; 10.0 cm⁻¹
  • Accuracy of contact conductivity simulation

    ±1 % set resistance
  • Temperature simulation

    Pt100: +25°C and +75°C
  • Temperature simulation accuracy

    ±1°C
  • Inductive Conduction Adapter Range

    1–2000 mS/cm (depending on the system used)
  • Inductive adapter cell constants

    K = 4-5.9 or 6-8 cm⁻¹
  • Inductive adapter accuracy

    ±1–1.5 %, depending on range
  • pH/ORP connections

    BNC and reference electrode connection
  • Contact Conductivity Simulator Connector

    5-pin connector, 1.1 m cable with open wire ends
  • Inductive adapter connectors

    2 mm test leads
  • Power supply

    pH/ORP simulator: 9V battery included
  • Ambient temperature

    0 to +50 °C (pH / ORP and contact conductivity simulators)
  • Housing material

    Powder-coated steel; induction adapter – polycarbonate
  • Simulator dimensions

    130.5 × 73 × 59mm
  • Inductive adapter dimensions

    103 × 52 × 59mm
  • Compatibility

    pH / ORP measuring transducers, 2-electrode conductivity meters; JUMO AQUIS 500 Ci inductive conductivity systems
  • Additional equipment

    BNC–BNC, BNC–N and BNC–Shield-Kon connecting cables
  • Applications

    Commissioning, calibration, verification and fault diagnosis of measurement systems

AVAILABLE MODELS

DOCUMENTS

  • Brochure: Liquid Analysis

    10.32 MB

    Download
  • Operating instructions: JUMO pH/redox simulator

    997.57 KB

    Download
  • Operating instructions: JUMO electrolytic conductivity simulator

    661.38 KB

    Download
  • Datasheet: pH, ORP and Conductivity Measurement Simulators and Calibration Adapters – 202711

    217.59 KB

    Download
  • Certificate: China RoHS – 20 – Simulators and Calibration Adapters

    98.5 KB

    Download
  • Calibration Guide: Inductive Conductivity Measurement Calibration Adapter, Type 202711/21

    273.23 KB

    Download
  • Order information: 202711

    114.63 KB

    Download
  • EU Declaration of Conformity: Simulators and Calibration Adapters

    162.23 KB

    Download