Badger Meter SeptiNet smart wastewater monitoring system

Optical spectrometric analyzers, Water analysis

Fields of application

Badger Meter SeptiNet is a smart wastewater monitoring system designed to measure hydrogen sulfide (H₂S) gas concentration and oxidation-reduction potential (ORP). The system ensures continuous control of wastewater networks, helps to identify the risk of odors, corrosion and hazardous gas formation early. Remote data transmission allows for effective monitoring of the condition of sewage networks.

 

Features:

  • Simultaneous monitoring of H₂S gas and ORP indicators
  • Continuous monitoring of wastewater networks
  • Remote data transfer to SCADA systems
  • Early detection of odors and corrosion risks
  • Setting warning and alarm limits
  • Data collection and analysis
  • Suitable for pumping stations, wells and wastewater treatment plants
  • SPECIFICATIONS
  • AVAILABLE MODELS
  • DOCUMENTS

SPECIFICATIONS

  • Type

    Smart wastewater quality monitoring system
  • Model

    SeptiNet
  • Manufacturer

    Badger Meter / s::can
  • Dedicated

    Monitoring of wastewater networks, pumping stations and treatment plants
  • Measured parameters

    Hydrogen sulfide (H₂S), ORP; flow data monitoring available
  • H₂S measurement principle

    Electrochemical sensor
  • H₂S measuring range

    Adjustable according to the limits of the selected sensor
  • H₂S measurement accuracy

    ±5–10 % measured values using F12D
  • ORP measurement range

    -1000…+1000 mV
  • ORP sensitivity

    0.2 mV
  • ORP stability

    2 mV in 24 hours.
  • H₂S analog output

    4-20 mA using F12D
  • Data transfer

    Through RTU to data analysis platform and SCADA
  • Available communication technologies

    2G, 3G, NB-IoT, LTE Cat M1 with Cello 4S RTU, depending on version
  • Data logging interval

    0.1-60 minutes.
  • Security class

    IP65 – F12D detector; IP68 – Cello 4S RTU
  • H₂S detector temperature

    -30…+60 °C (F12D)
  • ORP sensor temperature

    -5…+95 °C
  • Remote monitoring

    Yes
  • Alarm settings

    Programmable warning limits
  • Available H₂S detector versions

    F12D, F12iS, B12
  • Available accessories

    External RTU antenna, data transmission equipment, compatible with RTUs from other manufacturers