Ideal for combustion control in boilers, incinerators and furnaces.
Applications
O₂ measurement in non-combustible gas mixtures
Measuring principle
In-situ zirconia sensor
Scale
O ... 2 ... 50% Vd O2 (user-configurable)
Repeatability
<± 0,5 % PE
Linearity
<±2%PE
Response time (for 90%)
4 s ... 7 s
Analog output
4-20 mAcc or 0-1 Vcc
Contact outputs
6 points, SPST-NO contacts: high/low limit alarm calibration maintenance in progress, fault analyser, purging in progress, calibration in progress, fault analyser
Contact inputs
3 dry contacts: select from 7 options
Display
LCD backwired
Connectivity
RS-485 Modbus or HART
Optional functions
Combustion efficiency display, cleaning, automatic calibration, selection valve, flow meter
Controller installation
Panel or pipe mounting
Cable length between controller and detector
< 100m
Power supply
100-120 v ac or 200-240 v ac, 50/60 Hz