Piller UNIBLOCK™ UBTD+ – rotary diesel UPS

Rotary UPS, UPS

Fields of application

PILLER UNIBLOCK™ UBTD+ is a rotary diesel UPS, in which the motor generator, flywheel and diesel engine are mounted on a single base. Designed for critical infrastructure: data centers, industry and facilities that require a single integrated UPS and generator solution.

 

Features:

  • Single module power 500–2700 kW, parallel up to 40 MW
  • UPS and diesel engine in one device on a common base
  • Most grid failures do not require diesel start-up: POWERBRIDGE™ or batteries are used for the bridge
  • Fewer generator false starts and less engine wear
  • Diesel starts immediately or delayed from seconds to minutes
  • Voltage dips up to 50 % without disconnection; load surges up to 100 %; 99 % harmonic isolation
  • Highest partial and full load efficiency with connected storage; no power capacitors; service life of over 20 years
  • Low and medium voltage versions; air or water cooling; containerized version
  • SPECIFICATIONS
  • AVAILABLE MODELS
  • DOCUMENTS

SPECIFICATIONS

  • Manufacturer

    PILLAR
  • Series

    UNIBLOCK™ UBTD+
  • Device type

    Rotary diesel UPS
  • Power per module

    500–2700 kW
  • Maximum system power

    Up to 40 MW
  • Construction

    UNIBLOCK™ motor generator connected to a diesel engine via an overrunning clutch, in a single base frame
  • Efficiency

    Highest efficiency at part and full load with connected energy storage
  • Voltage

    Low or Medium (MV)
  • Diesel start delay

    Adjustable: from seconds to minutes
  • Engine options

    Different diesel engine variants
  • Output configuration

    Single output (100 % power as UPS) or dual output bus: UPS (critical) + short-circuit load
  • Double insulated busbar

    The generator winding supplies the critical bus, the motor winding supplies the short-circuit bus; the circuits are electrically isolated
  • Parallel connection

    MV: up to 40 MW; ZE: typically up to ~5 MW, up to 20 MW using isolated parallel connection
  • Redundancy schemes

    Isolated redundant, distributed redundant (N+1), IP-Bus up to 40 MW, system + system, hot-standby, parallel redundant
  • Voltage tolerance

    Drops up to 50 % nominal without disconnection; up to -30 % without storage energy
  • Power lines

    Critical and emergency can be separated or combined in one distribution
  • Harmonic isolation

    99 %
  • Cooling

    By air or cold water
  • Dimensions and weight

    According to the selected configuration
  • Applications

    Data centers, industry, critical infrastructure
  • Additional equipment available

    Containerized version

    Cooling with water from the building's cold water system

    Medium voltage version

    Battery bridge instead of POWERBRIDGE™