PILLER UNIBLOCK™ UBT+ – rotary uninterruptible power supplies (UPS) with motor generator and switching reactor, designed for data centers, industry, healthcare, banking and other critical infrastructure. Suitable for new and existing installations, normal and harsh environments.
Features:
Single unit capacity 500–2700 kW, parallel up to 40 MW
Efficiency up to 97 % when energy storage is connected
Without power capacitors and electric fans; service life of more than 20 years
Voltage drops up to 50 % without disconnection; up to -30 % without storage energy
100 % nonlinear load control and 100 % load surge control; 99 % harmonic isolation
Clears short circuits on the load side itself without using a bypass
Batteries (up to 30 min) or POWERBRIDGE™ flywheel
Low and medium voltage versions; containerized version
SPECIFICATIONS
AVAILABLE MODELS
DOCUMENTS
SPECIFICATIONS
Manufacturer
PILLAR
Series
UNIBLOCK™ UBT+
Device type
Rotary UPS (motor generator + switching choke)
Power per module
500–2700 kW
Maximum system power
Up to 40 MW (medium voltage)
Parallel connection
ZE (low voltage): typically up to ~5 MW, up to 20 MW using isolated parallel connection; MV: up to 40 MW, with individual or common chokes
Voltage
Low or Medium (MV)
Efficiency
Up to 97 % with connected energy storage
Energy storage
Batteries or POWERBRIDGE™ flywheel
Input power factor
Almost unique
Harmonic isolation
99 %
Cooling
Natural (machine fan impeller) or water (from building cold water)
Configurations
Standalone, with backup generators, with cogeneration; IP-Bus; DeRUPS™
Redundancy schemes
Hot reserve, parallel power, parallel reserved, isolated reserved, isolated parallel, system + system; common or separate bypass
Voltage tolerance
Drops up to 50 % nominal without disconnection; up to -30 % without storage energy
Load power factor
Wide lagging and overtaking range without power reduction
Backup generators
Can be remote from the UPS, in a different voltage range, connected to the input or output; power is selected independently of the UPS
Automatic power control
The number of operating devices is automatically adjusted to the load, maintaining the reservation level
Dimensions and weight
According to the selected configuration
Applications
Data centers, industrial, healthcare, finance, communications
Additional equipment available
Containerized version
Cooling with water from the building's cold water system
Medium voltage version
POWERBRIDGE™ kinetic storage instead of batteries
Integration with cogeneration and backup generators (DeRUPS™, IP-Bus)