Oil and gas, petrochemical and chemical industries, power generation, water treatment
Pressure
414 bar (6000 Psi)
Material
Stainless steel 316 L
Waterproofing
PTFE
Connection
1 Inlet - 1/2" NPT female
Assembly
The manifold is mounted directly on the transmitter.
All tests and manufacturing operations are carried out with the manifold mounted:
- Pressure and leak test at 1.5 x static pressure for differential pressure
for differential pressure transmitters, and at the permissible overpressure for gauge pressure or absolute transmitters
- Calibration with manufacturing equipment
Miscellaneous (depending on model)
Drain 1/4 "NPT
M10 mounting holes
1/4 "NPT trap/plug
Mounting holes Ø6.5
Applications
Closing and venting pressure measurement instruments
For aggressive gaseous and liquid media that are not highly viscous or crystallizing, even in aggressive environments
Special features
Low-wear design thanks to non-rotating spindle end in valve bonnet
Low torque and smooth operation of the valve handle, even at high pressure
Enhanced safety thanks to anti-ejection design of the valve bonnet
Valve seat leak-tested to BS6755 / ISO 5208 leak rate A
Combination of valve and hook-up on request
Product code | Adapter | Price |
---|---|---|
W3 | Without adapter | |
W9 | With adapter |