en
  • lt
  • en

Fuji Electric manometrinio slėgio jutiklis su sandarikliu – FKP F

Pressure sensors

Fields of application

Su diafragminiu sandarikliu slėgio jutiklis gali būti naudojamas plačiam taikymo spektrui: skysčio srauto matavimui, dujų srauto matavimui, garų srauto matavimui, skysčio lygio matavimui talpykloje, skysčio tankio matavimui arba slėgio matavimui esant žemai arba aukštai temperatūrai.

Features

  • Precise measurement even at low pressures
  • Accessible sensor installation and reading
  • Diaphragm seals can be mounted on all transmitter types
  • A wide range of possible applications
  • SPECIFICATIONS
  • AVAILABLE MODELS
  • DOCUMENTS

SPECIFICATIONS

  • Housing

    L- or T-shaped housing

  • Measuring ranges (kPa) [e.max.]

    130
    500
    3000
    10000

  • Weight per kg (without indicator)

    1.7 - 17

  • Accuracy

    ± 0.1% of the measurement range set as standard.

  • Materials in contact with the process

    Stainless steel 316 L, Stainless steel 316 L + Gilding

  • Case materials

    Low-copper aluminum alloy with polyester coating, or 316 L stainless steel

  • Membrane materials

    Stainless steel 316 L
    Hastelloy-C

  • Stability

    ± 0.2% of full scale for 10 years.

  • Elevation / Deletion

    From -100 to +100% of maximum scale

  • Scale setting range

    1 to 1/100 of maximum scale

  • Measurement cycle

    40 ms

  • Communication protocol

    HARTTM 7 communication protocol

  • Process temperature

    From +40° to +120°C (versions for higher temperatures are available)

  • Ambient temperature

    From -40° to +85 °C

  • Power supply

    10,5–45 V DC

  • Output signal / Load resistance

    4-20 mA / 250 Ω typical

  • Damping

    Configurable between 0.04 and 32 secs

  • Zero and span adjustment

    Via external sensor screw, local three-button display or HARTTM protocol

  • Electrical connections

    M20×1,5" / 1/2 – 14 NPT / Pg13,5

  • Options

    Digital indicator, degreasing treatment, oxygen service, chlorine service, additional stainless steel identification plate

AVAILABLE MODELS

Product codeElektrinis prijungimasMeasurement scaleApprovalSeparator modelPrice
FKPT61V6-2XLYY-0L/SA6VYSY1/2"NPTFrom 0 to 1300 mbarATEX - Explosion-proof by enclosureFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPT61V6-2XLYY-0L/SA7VYSY1/2"NPTFrom 0 to 1300 mbarATEX - Explosion-proof by enclosureFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPT61V6-2KLYY-0L/SA6VYSY1/2"NPTFrom 0 to 1300 mbarATEX - Intrinsic safetyFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPT61V6-2KLYY-0L/SA7VYSY1/2"NPTFrom 0 to 1300 mbarATEX - Intrinsic safetyFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPT61V6-2ALYY-0L/SA6VYSY1/2"NPTFrom 0 to 1300 mbarWithout approvalFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPT61V6-2ALYY-0L/SA7VYSY1/2"NPTFrom 0 to 1300 mbarWithout approvalFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPT63V6-2XLYY-0L/SA6VYSY1/2"NPTFrom 0 to 30 barATEX - Explosion-proof by enclosureFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPT63V6-2XLYY-0L/SA7VYSY1/2"NPTFrom 0 to 30 barATEX - Explosion-proof by enclosureFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPT63V6-2KLYY-0L/SA6VYSY1/2"NPTFrom 0 to 30 barATEX - Intrinsic safetyFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPT63V6-2KLYY-0L/SA7VYSY1/2"NPTFrom 0 to 30 barATEX - Intrinsic safetyFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPT63V6-2ALYY-0L/SA6VYSY1/2"NPTFrom 0 to 30 barWithout approvalFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPT63V6-2ALYY-0L/SA7VYSY1/2"NPTFrom 0 to 30 barWithout approvalFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPT62V6-2XLYY-0L/SA6VYSY1/2"NPTFrom 0 to 5000 mbarATEX - Explosion-proof by enclosureFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPT62V6-2XLYY-0L/SA7VYSY1/2"NPTFrom 0 to 5000 mbarATEX - Explosion-proof by enclosureFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPT62V6-2KLYY-0L/SA6VYSY1/2"NPTFrom 0 to 5000 mbarATEX - Intrinsic safetyFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPT62V6-2KLYY-0L/SA7VYSY1/2"NPTFrom 0 to 5000 mbarATEX - Intrinsic safetyFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPT62V6-2ALYY-0L/SA6VYSY1/2"NPTFrom 0 to 5000 mbarWithout approvalFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPT62V6-2ALYY-0L/SA7VYSY1/2"NPTFrom 0 to 5000 mbarWithout approvalFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPW61V6-2XLYY-0L/SA6VYSYM20×1.5From 0 to 1300 mbarATEX - Explosion-proof by enclosureFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPW61V6-2XLYY-0L/SA7VYSYM20×1.5From 0 to 1300 mbarATEX - Explosion-proof by enclosureFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPW61V6-2KLYY-0L/SA6VYSYM20×1.5From 0 to 1300 mbarATEX - Intrinsic safetyFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPW61V6-2KLYY-0L/SA7VYSYM20×1.5From 0 to 1300 mbarATEX - Intrinsic safetyFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPW61V6-2ALYY-0L/SA6VYSYM20×1.5From 0 to 1300 mbarWithout approvalFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPW61V6-2ALYY-0L/SA7VYSYM20×1.5From 0 to 1300 mbarWithout approvalFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPW63V6-2XLYY-0L/SA6VYSYM20×1.5From 0 to 30 barATEX - Explosion-proof by enclosureFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPW63V6-2XLYY-0L/SA7VYSYM20×1.5From 0 to 30 barATEX - Explosion-proof by enclosureFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPW63V6-2KLYY-0L/SA6VYSYM20×1.5From 0 to 30 barATEX - Intrinsic safetyFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPW63V6-2KLYY-0L/SA7VYSYM20×1.5From 0 to 30 barATEX - Intrinsic safetyFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPW63V6-2ALYY-0L/SA6VYSYM20×1.5From 0 to 30 barWithout approvalFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPW63V6-2ALYY-0L/SA7VYSYM20×1.5From 0 to 30 barWithout approvalFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPW62V6-2XLYY-0L/SA6VYSYM20×1.5From 0 to 5000 mbarATEX - Explosion-proof by enclosureFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPW62V6-2XLYY-0L/SA7VYSYM20×1.5From 0 to 5000 mbarATEX - Explosion-proof by enclosureFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPW62V6-2KLYY-0L/SA6VYSYM20×1.5From 0 to 5000 mbarATEX - Intrinsic safetyFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPW62V6-2KLYY-0L/SA7VYSYM20×1.5From 0 to 5000 mbarATEX - Intrinsic safetyFlange ANSI-300LB 4''- ISO PN 50 DN 100
FKPW62V6-2ALYY-0L/SA6VYSYM20×1.5From 0 to 5000 mbarWithout approvalFlange ANSI-300LB 3''- ISO PN 50 DN 80
FKPW62V6-2ALYY-0L/SA7VYSYM20×1.5From 0 to 5000 mbarWithout approvalFlange ANSI-300LB 4''- ISO PN 50 DN 100

DOCUMENTS

  • Certificate: SIL FCX-AIV-V6 series pressure transmitters

    198.3 KB

    Download
  • Certificate: UKCA declaration of conformity FCX-AIV-V6 series pressure transmitters

    1.22 MB

    Download
  • Manual: Pressure transmitters FCX-AIV V6

    7.97 MB

    Download
  • Software: Windows USB/HART modem drivers for pressure transmitter FCX

    63.57 KB

    Download
  • Software: Configuration of pressure transmitter FDT DTM pack for FCX V4 V5 VG V6

    7.06 MB

    Download
  • Datasheet : Diaphragm seals pressure transmitter FCX-AIV V6 FKP FKH

    1.62 MB

    Download
  • Brochure: Pressure transmitters FCX-AIV V6 series

    6.65 MB

    Download
  • Brochure : Pressure transmitters

    15.17 MB

    Download
  • Brochure: Measures for energy and the environment

    4.01 MB

    Download

SIMILAR PRODUCTS

  • Fuji Electric branduolinis absoliutaus slėgio jutiklis – FKM - NC - K3

    Pressure sensors

    Fuji Electric branduolinis absoliutaus slėgio jutiklis – FKM - NC - K3

  • Fuji Electric absoliutaus slėgio jutiklis su sandarikliu – FKH F

    Pressure sensors

    Fuji Electric absoliutaus slėgio jutiklis su sandarikliu – FKH F

    Inquire
  • Fuji Electric branduolinis slėgio jutiklis  – FKB - NC - K3

    Pressure sensors

    Fuji Electric branduolinis slėgio jutiklis – FKB - NC - K3