en
  • lt
  • en

Fuji Electric gauge pressure transmitter – FKG

Pressure sensors

Fields of application

The gauge pressure transmitter FKG can be used in a variety of industries to measure the pressure of any pressurized gas or fluid in pipes or vessels.

Features

  • High accuracy and reliability
  • Minimal influence on the environment
  • Wide measurement ranges
  • Economical
  • SPECIFICATIONS
  • AVAILABLE MODELS
  • DOCUMENTS

SPECIFICATIONS

  • Housing

    L- or T-shaped housing
  • Measuring ranges (kPa) [e.max.]

    130
    500
    3000
    10000
    50000
  • Weight per kg (without indicator)

    2.9 kg
  • Accuracy

    ± 0.065% of the measurement range set as standard. An accuracy of ±0.04% is also available as an option.
  • Materials in contact with the process

    Stainless steel 316 L, Hastelloy-C, Monel, Tantalue, Stainless steel 316 L + Gilding, Monel coating, Tantalue coating
  • Case materials

    Low-copper aluminum alloy with polyester coating, or 316 L stainless steel
  • Membrane materials

    Stainless steel 316 L
    Hastelloy-C
    Monel
    Tantalum
    Stainless steel 316 L and Gilding
    Gilding and Ceramics
  • Stability

    ±0.1% of maximum scale for 10 years
  • Elevation / Deletion

    From -100 to +100% of maximum scale
  • Scale setting range

    1 to 1/100 of maximum scale
  • Measurement cycle

    40ms
  • Communication protocol

    HARTTM 7 communication protocol
  • Process temperature

    From +40° to +120°C (versions for higher temperatures are available)
  • Ambient temperature

    From -40° to +85 °C
  • Power supply

    10.5-45V DC
  • Output signal / Load resistance

    4-20 mA / 250 Ω typical
  • Damping

    Configurable between 0.04 and 32 secs
  • Zero and span adjustment

    Via external sensor screw, local three-button display or HARTTM protocol
  • Electrical connections

    M20×1.5" / 1/2 - 14 NPT / Pg13.5
  • Options

    Digital indicator, degreasing treatment, oxygen service, chlorine service, additional stainless steel identification plate

AVAILABLE MODELS

Product code Electrical connection Digital indicator Approval Measurement scale Price
FKGT01V6-AXKYY-4L 1/2"NPT No indicator ATEX - Explosion-proof by enclosure From 0 to 1.3 bar
FKGT04V6-AXKYY-4L 1/2"NPT No indicator ATEX - Explosion-proof by enclosure From 0 to 100 bar
FKGT03V6-AXKYY-4L 1/2"NPT No indicator ATEX - Explosion-proof by enclosure From 0 to 30 bar
FKGT02V6-AXKYY-4L 1/2"NPT No indicator ATEX - Explosion-proof by enclosure From 0 to 5 bar
FKGT01V6-AKKYY-4L 1/2"NPT No indicator ATEX - Intrinsic safety From 0 to 1.3 bar
FKGT04V6-AKKYY-4L 1/2"NPT No indicator ATEX - Intrinsic safety From 0 to 100 bar
FKGT03V6-AKKYY-4L 1/2"NPT No indicator ATEX - Intrinsic safety From 0 to 30 bar
FKGT02V6-AKKYY-4L 1/2"NPT No indicator ATEX - Intrinsic safety From 0 to 5 bar
FKGT01V6-AAKYY-4L 1/2"NPT No indicator Without approval From 0 to 1.3 bar
FKGT04V6-AAKYY-4L 1/2"NPT No indicator Without approval From 0 to 100 bar
FKGT03V6-AAKYY-4L 1/2"NPT No indicator Without approval From 0 to 30 bar
FKGT02V6-AAKYY-4L 1/2"NPT No indicator Without approval From 0 to 5 bar
FKGT01V6-2XKYY-4L 1/2"NPT With indicator ATEX - Explosion-proof by enclosure From 0 to 1.3 bar
FKGT04V6-2XKYY-4L 1/2"NPT With indicator ATEX - Explosion-proof by enclosure From 0 to 100 bar
FKGT03V6-2XKYY-4L 1/2"NPT With indicator ATEX - Explosion-proof by enclosure From 0 to 30 bar
FKGT02V6-2XKYY-4L 1/2"NPT With indicator ATEX - Explosion-proof by enclosure From 0 to 5 bar
FKGT01V6-2KKYY-4L 1/2"NPT With indicator ATEX - Intrinsic safety From 0 to 1.3 bar
FKGT04V6-2KKYY-4L 1/2"NPT With indicator ATEX - Intrinsic safety From 0 to 100 bar
FKGT03V6-2KKYY-4L 1/2"NPT With indicator ATEX - Intrinsic safety From 0 to 30 bar
FKGT02V6-2KKYY-4L 1/2"NPT With indicator ATEX - Intrinsic safety From 0 to 5 bar
FKGT01V6-2AKYY-4L 1/2"NPT With indicator Without approval From 0 to 1.3 bar
FKGT04V6-2AKYY-4L 1/2"NPT With indicator Without approval From 0 to 100 bar
FKGT03V6-2AKYY-4L 1/2"NPT With indicator Without approval From 0 to 30 bar
FKGT02V6-2AKYY-4L 1/2"NPT With indicator Without approval From 0 to 5 bar
FKGR01V6-AXKYY-4L M20×1.5 No indicator ATEX - Explosion-proof by enclosure From 0 to 1.3 bar
FKGR04V6-AXKYY-4L M20×1.5 No indicator ATEX - Explosion-proof by enclosure From 0 to 100 bar
FKGR03V6-AXKYY-4L M20×1.5 No indicator ATEX - Explosion-proof by enclosure From 0 to 30 bar
FKGR02V6-AXKYY-4L M20×1.5 No indicator ATEX - Explosion-proof by enclosure From 0 to 5 bar
FKGR01V6-AKKYY-4L M20×1.5 No indicator ATEX - Intrinsic safety From 0 to 1.3 bar
FKGR04V6-AKKYY-4L M20×1.5 No indicator ATEX - Intrinsic safety From 0 to 100 bar
FKGR03V6-AKKYY-4L M20×1.5 No indicator ATEX - Intrinsic safety From 0 to 30 bar
FKGR02V6-AKKYY-4L M20×1.5 No indicator ATEX - Intrinsic safety From 0 to 5 bar
FKGR01V6-AAKYY-4L M20×1.5 No indicator Without approval From 0 to 1.3 bar
FKGR04V6-AAKYY-4L M20×1.5 No indicator Without approval From 0 to 100 bar
FKGR03V6-AAKYY-4L M20×1.5 No indicator Without approval From 0 to 30 bar
FKGR02V6-AAKYY-4L M20×1.5 No indicator Without approval From 0 to 5 bar
FKGR01V6-2XKYY-4L M20×1.5 With indicator ATEX - Explosion-proof by enclosure From 0 to 1.3 bar
FKGR04V6-2XKYY-4L M20×1.5 With indicator ATEX - Explosion-proof by enclosure From 0 to 100 bar
FKGR03V6-2XKYY-4L M20×1.5 With indicator ATEX - Explosion-proof by enclosure From 0 to 30 bar
FKGR02V6-2XKYY-4L M20×1.5 With indicator ATEX - Explosion-proof by enclosure From 0 to 5 bar
FKGR01V6-2KKYY-4L M20×1.5 With indicator ATEX - Intrinsic safety From 0 to 1.3 bar
FKGR04V6-2KKYY-4L M20×1.5 With indicator ATEX - Intrinsic safety From 0 to 100 bar
FKGR03V6-2KKYY-4L M20×1.5 With indicator ATEX - Intrinsic safety From 0 to 30 bar
FKGR02V6-2KKYY-4L M20×1.5 With indicator ATEX - Intrinsic safety From 0 to 5 bar
FKGR01V6-2AKYY-4L M20×1.5 With indicator Without approval From 0 to 1.3 bar
FKGR04V6-2AKYY-4L M20×1.5 With indicator Without approval From 0 to 100 bar
FKGR03V6-2AKYY-4L M20×1.5 With indicator Without approval From 0 to 30 bar
FKGR02V6-2AKYY-4L M20×1.5 With indicator Without approval From 0 to 5 bar

DOCUMENTS

  • Certificate: SIL FCX-AIV-V6 series pressure transmitters

    198.3 KB

    Download
  • Certificate: UKCA declaration of conformity FCX-AIV-V6 series pressure transmitters

    1.22 MB

    Download
  • Manual: Pressure transmitters FCX-AIV V6

    7.97 MB

    Download
  • Software: Windows USB/HART modem drivers for pressure transmitter FCX

    63.57 KB

    Download
  • Software: Configuration of pressure transmitter FDT DTM pack for FCX V4 V5 VG V6

    7.06 MB

    Download
  • Datasheet : Gauge pressure transmitter FCX-AIV V6 FKG

    931.95 KB

    Download
  • Brochure: Pressure transmitters FCX-AIV V6 series

    6.65 MB

    Download
  • Brochure : Pressure transmitters

    15.17 MB

    Download
  • Brochure: Measures for energy and the environment

    4.01 MB

    Download

SIMILAR PRODUCTS

  • Fuji Electric branduolinis absoliutaus slėgio jutiklis – FKM - NC - K3

    Pressure sensors

    Fuji Electric Nuclear Absolute Pressure Sensor – FKM - NC - K3

  • Fuji Electric branduolinis diferencinio slėgio jutiklis - FKC - NC - K3

    Pressure sensors

    Fuji Electric nuclear differential pressure sensor - FKC - NC - K3

  • Fuji Electric slėgio jutiklis su diafragminiu sandarikliu - FKB

    Pressure sensors

    Fuji Electric pressure sensor with diaphragm seal - FKB

    Inquire