Fuji Electric absolute pressure sensor – FKA

Pressure sensors

Fields of application

The FKA absolute pressure sensor allows for precise measurement of any compressed gaseous or liquid medium using a constant vacuum pressure as a reference point.

Features

  • Barometric pressure measurement
  • Not affected by atmospheric pressure
  • High repeatability and accuracy
  • Long-term stability
  • SPECIFICATIONS
  • AVAILABLE MODELS
  • DOCUMENTS

SPECIFICATIONS

  • Housing

    L- or T-shaped housing
  • Measuring ranges (kPa) [e.max.]

    16
    130
    500
    3000
  • Weight per kg (without indicator)

    2.9 kg
  • Accuracy

    ± 0.2% of the measurement range set as standard. An accuracy of ±0.1% is also available as an option.
  • Materials in contact with the process

    Stainless steel 316L, PVDF, Hastelloy C, Stainless steel 316L + gold plating
  • Case materials

    Low-copper aluminum alloy with polyester coating, or 316 L stainless steel
  • Membrane materials

    Stainless steel 316 L
    Hastelloy-C
    Monel
    Tantalum
  • Stability

    ± 0.2% of full scale for 10 years.
  • Elevation / Deletion

    From -100 to +100% of maximum scale
  • Scale setting range

    1 to 1/100 of maximum scale
  • Measurement cycle

    40ms
  • Communication protocol

    HARTTM 7 communication protocol
  • Process temperature

    From +40° to +120°C (versions for higher temperatures are available)
  • Ambient temperature

    From -40° to +85 °C
  • Power supply

    10.5-45V DC
  • Output signal / Load resistance

    4-20 mA / 250 Ω typical
  • Damping

    Configurable between 0.04 and 32 secs
  • Zero and span adjustment

    Via external sensor screw, local three-button display or HARTTM protocol
  • Electrical connections

    M20×1.5" / 1/2 - 14 NPT / Pg13.5
  • Options

    Digital indicator, degreasing treatment, oxygen service, chlorine service, additional stainless steel identification plate

AVAILABLE MODELS

Product code Electrical connection Digital indicator Measurement scale Approval Price
FKAT02V6-AXKYY-4L 1/2"NPT No indicator From 0 to 1.3 bar(a) ATEX - Explosion-proof by enclosure
FKAT02V6-AKKYY-4L 1/2"NPT No indicator From 0 to 1.3 bar(a) ATEX - Intrinsic safety
FKAT02V6-AAKYY-4L 1/2"NPT No indicator From 0 to 1.3 bar(a) Without approval
FKAT04V6-AXKYY-4L 1/2"NPT No indicator From 0 to 30 bar(a) ATEX - Explosion-proof by enclosure
FKAT04V6-AKKYY-4L 1/2"NPT No indicator From 0 to 30 bar(a) ATEX - Intrinsic safety
FKAT04V6-AAKYY-4L 1/2"NPT No indicator From 0 to 30 bar(a) Without approval
FKAT03V6-AXKYY-4L 1/2"NPT No indicator From 0 to 5 bar(a) ATEX - Explosion-proof by enclosure
FKAT03V6-AKKYY-4L 1/2"NPT No indicator From 0 to 5 bar(a) ATEX - Intrinsic safety
FKAT03V6-AAKYY-4L 1/2"NPT No indicator From 0 to 5 bar(a) Without approval
FKAT02V6-2XKYY-4L 1/2"NPT With indicator From 0 to 1.3 bar(a) ATEX - Explosion-proof by enclosure
FKAT02V6-2KKYY-4L 1/2"NPT With indicator From 0 to 1.3 bar(a) ATEX - Intrinsic safety
FKAT02V6-2AKYY-4L 1/2"NPT With indicator From 0 to 1.3 bar(a) Without approval
FKAT04V6-2XKYY-4L 1/2"NPT With indicator From 0 to 30 bar(a) ATEX - Explosion-proof by enclosure
FKAT04V6-2KKYY-4L 1/2"NPT With indicator From 0 to 30 bar(a) ATEX - Intrinsic safety
FKAT04V6-2AKYY-4L 1/2"NPT With indicator From 0 to 30 bar(a) Without approval
FKAT03V6-2XKYY-4L 1/2"NPT With indicator From 0 to 5 bar(a) ATEX - Explosion-proof by enclosure
FKAT03V6-2KKYY-4L 1/2"NPT With indicator From 0 to 5 bar(a) ATEX - Intrinsic safety
FKAT03V6-2AKYY-4L 1/2"NPT With indicator From 0 to 5 bar(a) Without approval
FKAR02V6-AXKYY-4L M20×1.5 No indicator From 0 to 1.3 bar(a) ATEX - Explosion-proof by enclosure
FKAR02V6-AKKYY-4L M20×1.5 No indicator From 0 to 1.3 bar(a) ATEX - Intrinsic safety
FKAR02V6-AAKYY-4L M20×1.5 No indicator From 0 to 1.3 bar(a) Without approval
FKAR04V6-AXKYY-4L M20×1.5 No indicator From 0 to 30 bar(a) ATEX - Explosion-proof by enclosure
FKAR04V6-AKKYY-4L M20×1.5 No indicator From 0 to 30 bar(a) ATEX - Intrinsic safety
FKAR04V6-AAKYY-4L M20×1.5 No indicator From 0 to 30 bar(a) Without approval
FKAR03V6-AXKYY-4L M20×1.5 No indicator From 0 to 5 bar(a) ATEX - Explosion-proof by enclosure
FKAR03V6-AKKYY-4L M20×1.5 No indicator From 0 to 5 bar(a) ATEX - Intrinsic safety
FKAR03V6-AAKYY-4L M20×1.5 No indicator From 0 to 5 bar(a) Without approval
FKAR02V6-2XKYY-4L M20×1.5 With indicator From 0 to 1.3 bar(a) ATEX - Explosion-proof by enclosure
FKAR02V6-2KKYY-4L M20×1.5 With indicator From 0 to 1.3 bar(a) ATEX - Intrinsic safety
FKAR02V6-2AKYY-4L M20×1.5 With indicator From 0 to 1.3 bar(a) Without approval
FKAR04V6-2XKYY-4L M20×1.5 With indicator From 0 to 30 bar(a) ATEX - Explosion-proof by enclosure
FKAR04V6-2KKYY-4L M20×1.5 With indicator From 0 to 30 bar(a) ATEX - Intrinsic safety
FKAR04V6-2AKYY-4L M20×1.5 With indicator From 0 to 30 bar(a) Without approval
FKAR03V6-2XKYY-4L M20×1.5 With indicator From 0 to 5 bar(a) ATEX - Explosion-proof by enclosure
FKAR03V6-2KKYY-4L M20×1.5 With indicator From 0 to 5 bar(a) ATEX - Intrinsic safety
FKAR03V6-2AKYY-4L M20×1.5 With indicator From 0 to 5 bar(a) Without approval

DOCUMENTS

  • Certificate: SIL FCX-AIV-V6 series pressure transmitters

    198.3 KB

    Download
  • Certificate: UKCA declaration of conformity FCX-AIV-V6 series pressure transmitters

    1.22 MB

    Download
  • Manual: Pressure transmitters FCX-AIV V6

    7.97 MB

    Download
  • Software: Windows USB/HART modem drivers for pressure transmitter FCX

    63.57 KB

    Download
  • Software: Configuration of pressure transmitter FDT DTM pack for FCX V4 V5 VG V6

    7.06 MB

    Download
  • Datasheet : Absolute pressure transmitter FCX-AIV V6 FKA

    955.89 KB

    Download
  • Brochure: Pressure transmitters FCX-AIV V6 series

    6.65 MB

    Download
  • Brochure : Pressure transmitters

    15.17 MB

    Download
  • Brochure: Measures for energy and the environment

    4.01 MB

    Download

SIMILAR PRODUCTS

  • Fuji Electric branduolinis manometrinis slėgio jutiklis – FYG – K3

    Pressure sensors

    Fuji Electric Nuclear Manometric Pressure Sensor – FYG – K3

  • Fuji Electric branduolinis slėgio jutiklis – FKE - NC - K3

    Pressure sensors

    Fuji Electric nuclear pressure sensor – FKE - NC - K3

  • Fuji Electric absoliutaus slėgio jutiklis – TA

    Pressure sensors

    Fuji Electric absolute pressure sensor – TA

    Inquire