en
  • lt
  • en

Fuji Electric Ultrasonic Nitrogen Gas Flow Meter – FWD-N

Flowmeters

Fields of application

These nitrogen flow meters are ideal for companies in the pharmaceutical, chemical and food industries.

Features

  • Quick, easy and cost-effective installation
  • Clear reading of nitrogen consumption
  • Nitrogen leak detection
  • Reliability and accuracy of measurements
  • Adaptable to different applications
  • Low maintenance costs
  • Resistant to harsh environments
  • Various pipe diameters available
  • SPECIFICATIONS
  • AVAILABLE MODELS
  • DOCUMENTS

SPECIFICATIONS

  • Pipe diameter (mm)

    DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN150, DN200
  • Power supply

    24 V DC ±10% or built-in battery type (battery life : approx.10 years at 20˚C)
  • Power consumption

    24 V DC, 1.5 W or less
  • Applicable fluid

    N₂ (diameter 25-80 mm)
  • Temperature and humidity of fluid

    10°C to 60°C, RH 90% or less
  • Working pressure

    Less than 1 MPa (gauge pressure)
  • Flow speed range min

    DN25: Flow rate range ±0.6–35 m³/h; ±2.0% accuracy from ±3.5–35 m³/h, ±5.0% accuracy from ±0.6–3.5 m³/h
    DN32: Flow rate range ±1.1–65 m³/h; ±2.0% accuracy from ±6.5–65 m³/h, ±5.0% accuracy from ±1.1–6.5 m³/h
    DN40: Flow rate range ±1.3–80 m³/h; ±2.0% accuracy from ±8–80 m³/h, ±5.0% accuracy from ±1.3–8 m³/h
    DN50: Flow rate range ±2.5–150 m³/h; ±2.0% accuracy from ±15–150 m³/h, ±5.0% accuracy from ±2.5–15 m³/h
    DN65: Flow rate range ±4–240 m³/h; ±2.0% accuracy from ±24–240 m³/h, ±5.0% accuracy from ±4–24 m³/h
    DN80: Flow rate range ±5–300 m³/h; ±2.0% accuracy from ±30–300 m³/h, ±5.0% accuracy from ±5–30 m³/h
    DN100: Flow rate range ±10–500 m³/h; ±2.0% accuracy from ±50–500 m³/h, ±5.0% accuracy from ±10–50 m³/h
    DN150: Flow rate range ±24–1200 m³/h; ±2.0% accuracy from ±120–1200 m³/h, ±5.0% accuracy from ±24–120 m³/h
    DN200: Flow rate range ±40–2000 m³/h; ±2.0% accuracy from ±200–2000 m³/h, ±5.0% accuracy from ±40–200 m³/h
  • Air flow rate conversion accuracy

    FWD025-080: ±2.5% of measurement (at 500 kPa, 25°C, dry air)
    FWD100-200: ±2.0% of measurement (at ≥ 300 kPa)
  • Display

    1st line: Totalized value (m3) 8-digit, Instantaneous flow (l/mm) 8-digit
    2nd line: Instantaneous flow (Nm3/h) 5-digit (4-digit after 2000), Pressure (kPa) 5-digit, Temperature (°C) 3-digit
  • Outputs (not available with battery supply)

    Current output: 4-20 mA DCC (±0.5% PE), max. load resistance. 400Ω, max. current output 22 mA
    Instantaneous flow, pressure or temperature

    Contact output: 2 contact outputs, max. load 24 V DC, 50 mA, max. frequency: 10 Hz
    Output 1: pulses (forward)
    Output 2: pulses (reverse), high/low alarm, system error
  • Process connection type

    ⌀25, ⌀32 mm: ⌀25 mm – Rc1, ⌀32 mm – Rc1-1/4
    ⌀40-⌀80 mm: Flange mounting (JIS10K)
    ⌀100-⌀200 mm: Flange mounting JIS10K
  • Mounting conditions (straight lengths)

    ⌀25, ⌀32 mm: 20D or more upstream, 5D or more downstream
    When used for bidirectional measurement, 20D or more downstream and upstream

    ⌀40-⌀200 mm: 10D or more upstream, 5D or more downstream
    When used for bidirectional measurement, 10D or more downstream and upstream
  • Materials of wetted parts

    Aluminum alloy, PPS, fluorosilicone rubber, etc.
  • Installation location

    Indoor or outdoor (IP64 equivalent)
  • Storage temperature

    -20°C to 70°C, non-condensing

AVAILABLE MODELS

Product code Diameter, connection system Power supply Measuring fluid Output, power cord Instruction manual Price
FWD100D2-A52-1 100mm / Flange mounting (JIS10K) 24V DC ±10 Nitrogen 5 meters With
FWD100D2-A02-1 100mm / Flange mounting (JIS10K) 24V DC ±10 Nitrogen Without With
FWD150D2-A52-1 150mm / Flange mounting (JIS10K) 24V DC ±10 Nitrogen 5 meters With
FWD150D2-A02-1 150mm / Flange mounting (JIS10K) 24V DC ±10 Nitrogen Without With
FWD200D2-A52-1 200mm / Flange mounting (JIS10K) 24V DC ±10 Nitrogen 5 meters With
FWD200D2-A02-1 200mm / Flange mounting (JIS10K) 24V DC ±10 Nitrogen Without With
FWD025D2-A52-1 25mm / Rc1 24V DC ±10 Nitrogen 5 meters With
FWD025D2-A02-1 25mm / Rc1 24V DC ±10 Nitrogen Without With
FWD032D2-A52-1 32mm / Rc1-1/4 24V DC ±10 Nitrogen 5 meters With
FWD032D2-A02-1 32mm / Rc1-1/4 24V DC ±10 Nitrogen Without With
FWD040D2-A52-1 40mm / Rc1-1/4 24V DC ±10 Nitrogen 5 meters With
FWD040D2-A02-1 40mm / Rc1-1/4 24V DC ±10 Nitrogen Without With
FWD065D2-A52-1 65mm / Mounting between flanges 24V DC ±10 Nitrogen 5 meters With
FWD065D2-A02-1 65mm / Mounting between flanges 24V DC ±10 Nitrogen Without With
FWD050D2-A52-1 50mm / Flange mounting 24V DC ±10 Nitrogen 5 meters With
FWD050D2-A02-1 50mm / Flange mounting 24V DC ±10 Nitrogen Without With
FWD080D2-A52-1 80mm / Mounting between flanges 24V DC ±10 Nitrogen 5 meters With
FWD080D2-A02-1 80mm / Mounting between flanges 24V DC ±10 Nitrogen Without With

DOCUMENTS

  • Certificate: EU Declaration of Conformity FWD ultrasonic inline flowmeter

    56.71 KB

    Download
  • Manual: In-line ultrasonic flowmeter for air and nitrogen gas FWD

  • Datasheet: Clamp-on ultrasonic flow meter for air and nitrogen gas FWD

    901.72 KB

    Download
  • Brochure: Ultrasonic flow meters for liquids, steam and gas

    7.07 MB

    Download
  • Brochure: Measures for energy and the environment

    4.01 MB

    Download

SIMILAR PRODUCTS

  • Fuji Electric nešiojamas ultragarsinis debitomatis – FSC

    Flowmeters

    Fuji Electric portable ultrasonic flowmeter – FSC

    Inquire
  • Fuji Electric kompaktiškas ultragarsinis debitomatis S-Flow – FSZ

    Flowmeters

    Fuji Electric compact ultrasonic flowmeter S-Flow – FSZ

    Inquire
  • Fuji Electric kelių kanalų biogeninių dujų debitomatis SOL BIOGAZ

    Flowmeters

    Fuji Electric multi-channel biogenic gas flow meter SOL BIOGAZ