Fuji Electric NDIR CO₂ analizatorius – ZFP9

Gas Analysers

Fields of application

The infrared CO2 analyser ZFP9 allows precise and reliable measurement of CO2 concentration in controlled horticulture - Greenhouses, Building Ventilation Systems and Controlled Atmosphere Storage Facilities.

Features

  • High-performance infrared system
  • Excellent stability and easy maintenance
  • Compact and lightweight (approx. 3 kg)
  • SPECIFICATIONS
  • AVAILABLE MODELS
  • DOCUMENTS

SPECIFICATIONS

  • Measurable components

    Measurement of CO₂ content in air

  • Measurement principles

    Single-beam NDIR

  • Measurement ranges

    0 ... 0.2 ... 20 %

  • Logic output functions

    Min/max alarm, preselection, flow direction, error message

  • Empty tube detection

    Separate electrode

  • Programming

    3 front panel buttons

  • Interface

    RS232 Modbus® RTU as standard
    RS485 Modbus® RTU, M-Bus, HART™ & Profibus-DP optional

  • Flow scale

    0.03 - 12 m/s

  • Repeatability

    ≤ ±1 %PE

  • Zero drift

    ≤ ±10% for 6 months

  • Response time (for 90%)

    ≤ 10 s

  • Gas sampling

    Extraction pump and filter

  • Power supply

    100 V, 115 V, 200 V, or 230 V AC, 50/60 Hz

  • Dimensions

    220 (W) x 257 (H) x 85 (D) mm

  • Weight

    Approx. 3 kg

AVAILABLE MODELS

Product codeOutput signalMeasurement scalePower supplyPrice
ZFP9GA230 to 100mV DC non-linearFrom 0 to 0,2 %115 V AC 50/60 Hz
ZFP9GA430 to 100mV DC non-linearFrom 0 to 0,2 %220 V AC 50/60 Hz
ZFP9GB234-20mA DC non-linearFrom 0 to 0,2 %115 V AC 50/60 Hz
ZFP9GB434-20mA DC non-linearFrom 0 to 0,2 %220 V AC 50/60 Hz
ZFP9AA230 to 100mV DC non-linearFrom 0 to 0,3 %115 V AC 50/60 Hz
ZFP9AA430 to 100mV DC non-linearFrom 0 to 0,3 %220 V AC 50/60 Hz
ZFP9AB234-20mA DC non-linearFrom 0 to 0,3 %115 V AC 50/60 Hz
ZFP9AB434-20mA DC non-linearFrom 0 to 0,3 %220 V AC 50/60 Hz
ZFP9BA230 to 100mV DC non-linearFrom 0 to 1 %115 V AC 50/60 Hz
ZFP9BA430 to 100mV DC non-linearFrom 0 to 1 %220 V AC 50/60 Hz
ZFP9BB234-20mA DC non-linearFrom 0 to 1 %115 V AC 50/60 Hz
ZFP9BB434-20mA DC non-linearFrom 0 to 1 %220 V AC 50/60 Hz
ZFP9DA230 to 100mV DC non-linearFrom 0 to 10 %115 V AC 50/60 Hz
ZFP9DA430 to 100mV DC non-linearFrom 0 to 10 %220 V AC 50/60 Hz
ZFP9DB234-20mA DC non-linearFrom 0 to 10 %115 V AC 50/60 Hz
ZFP9DB434-20mA DC non-linearFrom 0 to 10 %220 V AC 50/60 Hz
ZFP9EA230 to 100mV DC non-linearFrom 0 to 20 %115 V AC 50/60 Hz
ZFP9EA430 to 100mV DC non-linearFrom 0 to 20 %220 V AC 50/60 Hz
ZFP9EB234-20mA DC non-linearFrom 0 to 20 %115 V AC 50/60 Hz
ZFP9EB434-20mA DC non-linearFrom 0 to 20 %220 V AC 50/60 Hz
ZFP9CA230 to 100mV DC non-linearFrom 0 to 5 %115 V AC 50/60 Hz
ZFP9CA430 to 100mV DC non-linearFrom 0 to 5 %220 V AC 50/60 Hz
ZFP9CB234-20mA DC non-linearFrom 0 to 5 %115 V AC 50/60 Hz
ZFP9CB434-20mA DC non-linearFrom 0 to 5 %220 V AC 50/60 Hz

DOCUMENTS

  • Certificate: UKCA analyser of CO₂ infrared ZFP9

    77.56 KB

    Download
  • Certificate: EU declaration of conformity analyser of CO₂ infrared ZFP9

    71.84 KB

    Download
  • Manual: analyser of CO₂ infrared ZFP9

    884.86 KB

    Download
  • Datasheet : NDIR CO₂ analyser ZFP9

    721.93 KB

    Download
  • Brochure: Gas analysers, reliable solutions for gas analysis

    8.47 MB

    Download
  • Application : Increase the yield and the quality of greenhouse crops with an accurate CO2 control

    711.53 KB

    Download
  • Brochure: Measures for energy and the environment

    4.01 MB

    Download

SIMILAR PRODUCTS

  • Fuji Electric šiluminio laidumo dujų analizatorius EX zonoms ZAFE

    Gas Analysers

    Fuji Electric šiluminio laidumo dujų analizatorius EX zonoms ZAFE

  • Fuji Electric cirkonio deguonies zondas – ZFK8

    Gas Analysers

    Fuji Electric cirkonio deguonies zondas – ZFK8

  • Fuji Electric dūmų dujų drėgmės matuoklis – DELTA-02

    Gas Analysers

    Fuji Electric dūmų dujų drėgmės matuoklis – DELTA-02