Assembly
In-line (above conveyor/hopper/line)
Adjustable distance to the product (stand-off)
Compatible with Scanframe (profile scanning)
Measuring principle
Near-IR (NIR) reflectance method, multi-channel filters
Measurement range
Humidity: 0.1-95 % (depends on material and calibration)
Accuracy (typ.)
±0.1 % (for calibrated materials)
Response time/sampling
Real-time indication (typically up to several meters/s; depends on configuration)
Temperature
Product temp. measurement: 0…400 °C (32…752 °F)
Ambient operating temperature: −20…+80 °C (−4…176 °F)
Housing
Aluminium
Protection
High protection in industry
Outputs and connections
Analog: 4-20 mA
Digital: Modbus RTU/TCP, Profibus, Profinet, Ethernet, DeviceNet, RS-485, IoT (depending on configuration)
Power supply
Industrial power supply (typically 24 V DC or according to project specification)
< 15-30 W (typ.) depending on configuration
Mechanics
Compact sensor with industrial connectors; frame/stand mounting
Applications
For bulk materials, biomass, grain, concrete and aggregates
For paper, cardboard, food industry (biscuits, flour, sugar, etc.)
For industrial process lines where constant humidity control is required
Accessories (as needed)
Protective window, air knife, mounting frames, Scanframe
Notes
Exact values may vary depending on material, optics, and calibration.